TCAT-2 Temperature Controller

Model:TCAT-2

 TCAT-2 Temperature Controller "Animal Temperature Controller"

  • Details
  • Specifications
  • Applications
  • Support
  •  TCAT-2 Temperature Controller with RET-3 Temperature probe and HL-1, Heat Lamp

    Our new TCAT-2 family of general purpose PID Autotuning Controllers provides accurate temperature control in a variety of laboratory applications. Combined with a heat lamp or heating pad, the TCAT-2 may be used to maintain the body temperature of anesthetized animals during surgery or stereotaxic procedures. Small animal cages are easily warmed with a heat lamp. The TCAT-2 may also be used in cooling applications, such as to control independent perfusate cooling systems. Realizing that laboratory applications are diverse, Physitemp can provide several versions of the TCAT Controller. The model specified depends on whether a laboratory has a general or specific need for the controller:

    TCAT-2AC:
    This version controls only AC powered heating or cooling devices such as a heat lamp. It is the least costly.

    TCAT-LV:
    This model provides a low-voltage DC output for electrically sensitive applications where AC frequencies might interfere with other monitoring devices. It comes standard with a built in DC power supply designed to operate with our HP-1M Heating Plate for small rodents. The TCAT-2LV utilizes a dual set point control circuit to prevent a heating element from overshooting the control point due to thermal lag in the control system. This is an important feature in preventing burns due to incorrect control settings or faulty feedback sensor. On a custom basis, we can provide a variety of DC power supplies Depending on the load power requirements.

    TCAT-2DF:
    This is a combination version which includes both an AC outlet for controlling primarily resistance loads such as heat lamps, AC powered warming blankets and a low-voltage, low-noise" DC output for heating pads. This version allows you to control a variety of different loads.

    All TCAT-2 versions may be used with any of our extensive line of accurate Type T thermocouple probes, which act as the temperature feedback sensor. Most commonly used are the RET series of animal rectal probes, but the IT series of implantable flexible probes and MT series of needle probes may also be used depending on the specific application. All instruments are designed to operate on a 110V or 230V AC supply.

    The unit comes in a durable baked enamel painted aluminum housing. Adjustable front feet allow the user to raise the front of controller to provide a more convenient viewing angle.

    A heat/cool switch is provided when using the controller with cooling devices such as small refrigeration compressors or thermoelectric stages. In the cooling mode it inverts the control function and shuts off the load when feedback sensor temperature falls below the set point. A small lamp on the front of the control unit indicates when power is being applied to the load.

    The TCAT-2 is simple to set-up; connect the feedback sensor to the animal and to the back of the controller, connect the heating pad, blanket, lamp or cooling device to the appropriate outlet on the rear of the controller. Adjust the set temperature as required (lower green display) according to the instruction label on top of the instrument. The set temperature is stored in memory after the unit is switched off.

    Features

    Controls heating blankets heat lamps or heating pad.

    Can be used for both heating and cooling applications.

    110 to 230V AC line operation

    Control Range of -100 to +400°C

    Resolution 0.1°C

  •  

     

    Specifications

    Resolution

     

    ±0.1°C

    Accuracy

     

    ± 0.5°C

    Range

     

    Ambient +2° to 60°C

    Readout

     

    Dual display of Set (red) and Run(red) temperatures

    Max AC Power Output with resistive load

     

    700 watts (Does not apply to TCAT-2LV)

    DC Output Rating:

     

    TCAT-2DF and TCAT-2LV: 12V DC, 2 Amps Max. Custom output voltages available upon request(Does not apply to TCAT-2AC)

    AC ground leakage current

     

    less than 1 millamp at 110 V AC

    Dual Setpoint Protection Feature

     

    TCAT-2DF and TCAT-2LV onlyadditional heating pad feedback sensor prevents temperature exceeding 45°C.

    Dimensions

     

    7 1/4" W x 4 3/8" H x 10" D

    Weight

     

    Less than 5 lbs.

    Power Supply

     

    110V or 220 V AC

  •  Please call for details 

  •  Please call for details 

ICP備案號: 滬ICP備15057650號-1 滬公網(wǎng)安備31011202005471
雷萌生物科技(上海)有限公司 保留所有版權.

首頁   |   產(chǎn)品中心   |   產(chǎn)品應用   |   技術支持   |   新聞中心   |   關于我們   |   ibidi官網(wǎng)
主站蜘蛛池模板: 高清不卡二卡三卡四卡免费| 亚洲区小说区图片区qvod| 国产第一页浮力影院入口| 免费人成在线观看vr网站| av天堂久久天堂av色综合| 久久中文字幕av不卡一区二区| 久久精品蜜芽亚洲国产av| 成人性做爰aaa片免费看曹查理| 潮喷失禁大喷水av无码| 狠狠色噜噜狠狠狠狠米奇777| 色综合色狠狠天天综合网| 人人狠狠久久亚洲综合88| 成人亚洲欧美久久久久| 男女做爰猛烈啪啪吃奶伸舌头下载| 亚洲人成电影网站色迅雷| 亚洲第一最快av网站| 六月丁香综合在线视频| 美女粉嫩饱满的一线天mp4| 九九九精品成人免费视频| 亚洲性线免费观看视频成熟| 国产免费福利在线视频| 超级大爆乳奶牛被调教出奶水| 国产精品午夜爆乳美女视频| 国产在不卡免费一区二区三| 久热这里在线精品| 欧美 亚洲 日韩 中文2019| 人妻插b视频一区二区三区| 亚洲国产色播av在线| 被拉到野外强要好爽黑人| 国产无套露脸在线观看| 在线精品自偷自拍无码| 69综合精品国产二区无码| 国产一区日韩二区欧美三区| 邻居少妇张开腿让我爽了在线观看| 欧美极品少妇×xxxbbb| 荫道bbwbbb高潮潮喷| 日本一本二本三区免费 | 亚洲一区 日韩精品 中文字幕| 国产精品99久久精品爆乳| 精品久久久久国产免费| 2020国产精品久久精品|